会議発表論文 Effects of gap distance on VIV of a parallel cable-stayed bridge

Park, Jin  ,  Kim, Ho-Kyung

内容記述
The effects of gap distance on vortex-induced vibration of two parallel section models are studied in a wind tunnel. Since two section models have similar cross-section and dynamic properties, the position whether the deck is located in upstream or downstream is the most significant difference between two decks in this study. Wind velocity at the beginning of the vibration of the downstream deck is affected by vortices from upstream deck. This is connected with separation flows from upstream deck through flow field observation.
Meeting Information: First International Symposium on Flutter and its Application (May 15-17, 2016. Mielparque-tokyo), Minato-ku, Tokyo, Japan
Physical characteristics: Original contains color illustrations
形態: カラー図版あり