Journal Article Measuring laser carrier-envelope-phase effects in the noble gases with an atomic hydrogen calibration standard

Khurmi, Champak  ,  Wallace, W. C.  ,  Sainadh U, Satya  ,  Ivanov, I. A.  ,  Kheifets, A. S.  ,  Tong, X. M.  ,  Litvinyuk, I. V.  ,  Sang, R. T.  ,  Kielpinski, D.

96 ( 1 )  , p.013404 , 2017-07 , American Physical Society
ISSN:2469-9926
NCID:AA10764867
Description
We present accurate measurements of carrier-envelope-phase effects on ionization of the noble gases with few-cycle laser pulses. The experimental apparatus is calibrated by using atomic hydrogen data to remove any systematic offsets and thereby obtain accurate CEP data on other generally used noble gases such as Ar, Kr, and Xe. Experimental results for H are well supported by exact time-dependent Schrödinger equation theoretical simulations; however, significant differences are observed in the case of the noble gases.
Full-Text

https://tsukuba.repo.nii.ac.jp/?action=repository_action_common_download&item_id=41990&item_no=1&attribute_id=17&file_no=1

Number of accesses :  

Other information