学術雑誌論文 Registration error of the liver CT using deformable image registration of MIM Maestro and Velocity AI

Fukumitsu, Nobuyoshi  ,  Nitta, Kazunori  ,  Terunuma, Toshiyuki  ,  Okumura, Toshiyuki  ,  Numajiri, Haruko  ,  Oshiro, Yoshiko  ,  Ohnishi, Kayoko  ,  Mizumoto, Masashi  ,  Aihara, Teruhito  ,  Ishikawa, Hitoshi  ,  Tsuboi, Koji  ,  Sakurai, Hideyuki

17 ( 1 )  , p.30 , 2017-05 , BioMed Central
ISSN:1471-2342
NII書誌ID(NCID):AA12035074
内容記述
BackgroundUnderstanding the irradiated area and dose correctly is important for the reirradiation of organs that deform after irradiation, such as the liver. We investigated the spatial registration error using the deformable image registration (DIR) software products MIM Maestro (MIM) and Velocity AI (Velocity).MethodsImage registration of pretreatment computed tomography (CT) and posttreatment CT was performed in 24 patients with liver tumors. All the patients received proton beam therapy, and the follow-up period was 4–14 (median: 10) months. We performed DIR of the pretreatment CT and compared it with that of the posttreatment CT by calculating the dislocation of metallic markers (implanted close to the tumors).ResultsThe fiducial registration error was comparable in both products: 0.4–32.9 (9.3 ± 9.9) mm for MIM and 0.5–38.6 (11.0 ± 10.0) mm for Velocity, and correlated with the tumor diameter for MIM (r = 0.69, P = 0.002) and for Velocity (r = 0.68, P = 0.0003). Regarding the enhancement effect, the fiducial registration error was 1.0–24.9 (7.4 ± 7.7) mm for MIM and 0.3–29.6 (8.9 ± 7.2) mm for Velocity, which is shorter than that of plain CT (P = 0.04, for both).ConclusionsThe DIR performance of both MIM and Velocity is comparable with regard to the liver. The fiducial registration error of DIR depends on the tumor diameter. Furthermore, contrast-enhanced CT improves the accuracy of both MIM and Velocity.
本文を読む

https://tsukuba.repo.nii.ac.jp/?action=repository_action_common_download&item_id=41385&item_no=1&attribute_id=17&file_no=1

このアイテムのアクセス数:  回

その他の情報