学術雑誌論文 Emission of Particulate Matter 2.5 (PM2.5) from Sewage Sludge Incinerators in Japan

Shiota, Kenji  ,  Takaoka, Masaki  ,  Yamaguchi, Shuji  ,  Oshita, Kazuyuki

33 ( 11 )  , pp.1286 - 1294 , 2015-04-15 , Taylor & Francis Group
ISSN:0737-3937
NII書誌ID(NCID):AA10636517
内容記述
Selected Papers from the 4th European Conference on Sludge Management (ECSM 2014)
Because fine particulate matter ≤2.5 µm in diameter (PM2.5) causes health problems, PM2.5 emissions are of concern. However, little research on stationary sources has been conducted. To determine the concentration and filtration behavior of PM2.5, dust was collected from five fluid-bed sewage sludge incinerators (SSIs) sorted by particle size using cascade impactors. The average PM2.5 concentration was 0.00014–4.8 mg/Nm3. The total estimated amount of PM2.5 emissions from the SSIs for all plants in Japan was 0.96–8.9 tons/year. Since the SSIs with dry Electrostatic Precipitators (EP) contributed 75–99% of the total emissions, replacing dry EPs with bag filters would significantly reduce the PM2.5 emissions from SSI.
本文を読む

http://repository.kulib.kyoto-u.ac.jp/dspace/bitstream/2433/201955/1/07373937.2015.1026977.pdf

このアイテムのアクセス数:  回

その他の情報